ACCUMAX ELECTRONIC DISPENSER

The electronic pipette organically combines unsurpassed performance, excellent ergonomics and an intuitive graphical interface. This innovative tool not only satisfies, but also anticipates the user’s requirements by adapting its functionality accordingly. With its advanced design, it effortlessly understands and responds to the user’s needs, ensuring optimal accuracy and correctness. Experience the perfect combination of exceptional performance, enhanced user experience, and user-friendly interface, making pipetting easy. Enhance your pipetting experience with this state-of-the-art tool that allows you to achieve outstanding results with ease.

Intelligent sleep mode to save battery power, increasing battery efficiency by 40%.%
Calibrated according to ISO 8655-6 standard in an ISO 17025 accredited calibration laboratory for complete peace of mind
Exceptionally light weight for easy and painless pipetting even with prolonged use.
Saves and remembers 3 frequently used modes for quick and convenient use
Additionally (optional): Charging stand. Strong and durable charging stand. Charge the pipette when not in use.
Additionally (optional): Acrylic stand

AE-10
Volume range: 0.5–10 µl
Test Volume / Inaccuracy (±%) / Inaccuracy [µl] / Error (±%) / Error [µl]:
– 2.5 µl: 2.5% / 0.03 µl / 1.8% / 0.02 µl
– 5 µl: 2% / 0.10 µl / 1% / 0.05 µl
– 10 µl: 1% / 0.10 µl / 0.6% / 0.06 µl

AE-100
Volume range: 5-100 µl
– 10 µl: 3% / 0.30 µl / 1% / 0.10 µl
– 50 µl: 1% / 0.50 µl / 0.5% / 0.25 µl
– 100 µl: 0.8% / 0.80 µl / 0.2% / 0.20 µl

AE-200
Volume range: 10-200 µl
– 20 µl: 2.5% / 0.50 µl / 0.7% / 0.14 µl
– 100 µl: 0.7% / 0.70 µl / 0.3% / 0.30 µl
– 200 µl: 0.6% / 1.20 µl / 0.2% / 0.40 µl

AE-1000
Volume range: 50-1000 µl
– 100 µl: 3% / 3.00 µl / 0.6% / 0.60 µl
– 500 µl: 1% / 5.00 µl / 0.4% / 2.00 µl
– 1000 µl: 0.6% / 6.00 µl / 0.2% / 2.00 µl

AE5000
Volume range: 250-5000 µl
– 500 µl: 2.4% / 12.00 µl / 0.6% / 3.00 µl
– 2500 µl: 1.2% / 30.00 µl / 0.25% / 6.25 µl
– 5000 µl: 0.6% / 30.00 µl / 0.2% / 10.00 µl

AE8-10
Volume range: 0.5–10 µl
Test Volume / Inaccuracy (±%) / Inaccuracy [µl] / Error (±%) / Error [µl]:
– 1 µl: 8% / 0.08 µl / 5% / 0.05 µl
– 5 µl: 4% / 0.20 µl / 2% / 0.10 µl
– 10 µl: 2% / 0.20 µl / 1% / 0.10 µl

AE8-20
Volume range: 2-20 µl
– 2 µl: 7% / 0.14 µl / 3% / 0.06 µl
– 10 µl: 3% / 0.30 µl / 2% / 0.20 µl
– 20 µl: 2% / 0.40 µl / 1.6% / 0.32 µl

AE8-100
Volume range: 5-100 µl
– 10 µl: 3% / 0.30 µl / 2% / 0.20 µl
– 50 µl: 1% / 0.50 µl / 0.8% / 0.40 µl
– 100 µl: 0.8% / 0.80 µl / 0.3% / 0.30 µl

AE8-200
Volume range: 10-200 µl
– 20 µl: 5% / 1.00 µl / 1.4% / 0.28 µl
– 100 µl: 1% / 1.00 µl / 0.4% / 0.40 µl
– 200 µl: 0.7% / 1.40 µl / 0.25% / 0.50 µl

AE8-300
Volume range: 15-300 µl
– 30 µl: 3% / 0.90 µl / 1% / 0.30 µl
– 150 µl: 1% / 1.50 µl / 0.5% / 0.75 µl
– 300 µl: 0.6% / 1.80 µl / 0.3% / 0.90 µl

AE12-10
Volume range: 0.5–10 µl
Test Volume / Inaccuracy (±%) / Inaccuracy [µl] / Error (±%) / Error [µl]:
– 1 µl: 8% / 0.08 µl / 5% / 0.05 µl
– 5 µl: 4% / 0.20 µl / 2% / 0.10 µl
– 10 µl: 2% / 0.20 µl / 1% / 0.10 µl

AE12-20
Volume range: 2-20 µl
– 2 µl: 7% / 0.14 µl / 3% / 0.06 µl
– 10 µl: 3% / 0.30 µl / 2% / 0.20 µl
– 20 µl: 2% / 0.40 µl / 1.6% / 0.32 µl

AE12-100
Volume range: 5-100 µl
– 10 µl: 3% / 0.30 µl / 2% / 0.20 µl
– 50 µl: 1% / 0.50 µl / 0.8% / 0.40 µl
– 100 µl: 0.8% / 0.80 µl / 0.3% / 0.30 µl

AE12-200
Volume range: 10-200 µl
– 20 µl: 5% / 1.00 µl / 1.4% / 0.28 µl
– 100 µl: 1% / 1.00 µl / 0.4% / 0.40 µl
– 200 µl: 0.7% / 1.40 µl / 0.25% / 0.50 µl

AE12-300
Volume range: 15-300 µl
– 30 µl: 3% / 0.90 µl / 1% / 0.30 µl
– 150 µl: 1% / 1.50 µl / 0.5% / 0.75 µl
– 300 µl: 0.6% / 1.80 µl / 0.3% / 0.90 µl

Scroll to Top